HomeSitemap ReferencesAbout SelkaContact usNewsletter
  

 Products:  Trainings Systems » Generation and Distribution of Electrical Energy » EGP 1.1
Manufacturer Info
Lucas-Nülle
Other products
Products
   High/Low Voltage Electrical Distribution Boards, Controls and SCADA-GPRS Systems Design-Production


   Engineering Mechanics and Machine Elements


   Mechatronics


   Thermodynamics, Heating and Sanitary Systems


   Fluid Mechanics and Hydrology


   Process Engineering


   Automotive


   Apprenticeship workshop equipment


 Trainings Systems
   Electrical Engineering
   Electronics Engineering
   Digital Technology
   Electrical Installation Engineering
     Generation and Distribution of Electrical Energy
     Automation Technology, Process Control, Measurement Technology
     Electric Machines, Power Electronics, Drives
     Information and Communication Technology
     Automotive Technology


   Measuring & Test Instruments


   CNC Control Software


   Biology / Anatomy


   Physics


   Chemistry


   Biology-Physics-Chemistry PC Based Systems



View All Products
Your Inquiry
Your inquiry cart contains 0 items
Manufacturers


View All Manufacturers
Who's online?
There currently are 135   guests online.
previous Product3/7 next

EGP 1.1: Electric Power Generation

Print Ask to this Articlel

Electric Power Generation

Product Details


Generator and Generator Protection

To effectively protect generators against internal and external faults, a multitude of protection devices is required. The main protection is provided by a generator differential protection device, which detects faults such as short-circuit, double line-to-ground fault, short circuits in the windings or individual windings. The LN training system, "Generator Differential Protection" presented here is only a part of the systems available dealing with the subject of generator protection. In the LN training system, "Generator Differential Protection", the protection relay is connected via a current transformer, as is usual in practice. A 1kW three-phase machine with smooth-core rotor, is used as a generator. A DC dynamometer provides the drive.
The protection relay used here, is a digital type and the parameters can be set by means of the controls on the front panel, or with the appropriate software (optional).

Topics covered

EGP 1.1 Generator Differential Protection

  • Calculating the pull-in values
  • Fault recognition within the protected area
  • Switch-off and de-excitation of the generator
  • Detecting symmetric and asymmetric faults

Digital generator differential protection relay